-Author name in bold denotes the presenting author
-Asterisk * with author name denotes a Non-ASH member
Clinically Relevant Abstract denotes an abstract that is clinically relevant.

PhD Trainee denotes that this is a recommended PHD Trainee Session.

Ticketed Session denotes that this is a ticketed session.

4180 Next Generation Flow (NGF): A High Sensitive Technique to Detect Circulating Peripheral Blood (PB) Clonal Plasma Cells (cPC) in Patients with Newly Diagnosed of Plasma Cell Neoplasms (PCN)

Myeloma: Biology and Pathophysiology, excluding Therapy
Program: Oral and Poster Abstracts
Session: 651. Myeloma: Biology and Pathophysiology, excluding Therapy: Poster III
Monday, December 7, 2015, 6:00 PM-8:00 PM
Hall A, Level 2 (Orange County Convention Center)

*Luzalba Sanoja-Flores, M.Sc.1,2*, *Bruno Paiva, PhD3,4*, Juan A Flores-Montero, MD1,2*, Noemi Puig, MD, PhD5*, Leire Burgos4*, Omar García, PhD2*, Felipe Prosper, MD6, Juana Merino, MD PhD3*, Maria Belen Vidriales, MD, PhD5*, Maria-Victoria Mateos7, Ramon Garcia, MD7*, Luis Palomera, MD PhD8*, Rafael Rios9*, María Consuelo Cañizo, MD, PhD10*, Brian G M Durie11, Jacques J.M. van Dongen12, Jesus San Miguel, MD PhD3,4* and Alberto Orfao, MD, PhD1,2

1Servicio General de Citometría (NUCLEUS) and Department of Medicine, University of Salamanca, Salamanca, Spain
2Cancer Research Center (IBMCC-CSIC/USAL-IBSAL), Salamanca, Spain
3Department of Hematology and Immunology, Clinica Universidad de Navarra, Pamplona, Spain
4Centro de Investigación Médica Aplicada, University of Navarra, Clínica Universidad de Navarra, Pamplona, Spain
5Department of Hematology, Hospital Universitario de Salamanca, Salamanca, Spain
6Clinica Universidad de Navarra, Pamplona, Spain
7Department of Hematology, University Hospital of Salamanca, Salamanca, Spain
8Department of Hematology, Hospital Universitario Lozano Blesa, Zaragoza, Spain
9Hospital Virgen de las Nieves, Granada, Spain
10Hematology, Salamanca Universitary Hospital, Salamanca, Spain
11Cedars-Sinai Outpatient Cancer Center at the Samuel Oschin Comprehensive Cancer Institute, Los Angeles, CA
12Department of Immunology, Erasmus MC University Medical Center Rotterdam, Rotterdam, Netherlands

Introduction: Previous studies have shown that cPC can be detected in PB by conventional flow cytometry (FC) in around 70% of multiple myeloma (MM) and 37% of monoclonal gammopathy of undetermined significance (MGUS) patients at diagnosis. Its presence in MGUS has been associated with a higher risk of malignant transformation. We here investigated the utility and sensitivity of the EuroFlow-IMF NGF-MM minimal residual disease (MRD) approach for detecting circulating cPC in PB of patients with PCN.

Methods: A total of 137 samples (including 71 PB and 66 bone marrow -BM- paired samples) from 71 newly-diagnosed PCN patients (37 MGUS; 21 MM; 5 SMM and 8 solitary plasmacytomas -SP-), plus 6 PB samples from healthy controls, were studied. Samples were processed following the EuroFlow Bulk Lysis Standard Operating Protocol (SOP) and stained with the EuroFlow-IMF MM MRD panel (Tube 1:CD138BV421/CD27BV510/CD38FITC/CD56PE/CD45PerCP-Cy5.5/CD19PE-Cy7/CD117APC/CD81APC-C750, and; Tube 2: identical to Tube 1 except for CyKappaAPC/CyLambdaAPC-C750). A median of 10.6 x106 events (range: 1.7 x106- 15.7x106) were measured for PB samples using a FACSCanto II (BD Biosciences, San Jose, USA) instrument. Data were analyzed using the Infinicyt software (version 1.8.0RC6; Cytognos SL, Salamanca, Spain). Risk stratification of MGUS patients was established by the Mayo Clinic index. ROC analysis was used to define a cut-off to distinguish between MM and MGUS cases according to the percentage and absolute number of circulating PB cPC.

Results: Overall, cPC were detected in the PB of all MM and SMM cases studied (100%) and more than half of MGUS patients (60%; p=0.005), while constantly absent in the eight patients with SP. Upon classifying MGUS patients according to the Mayo Clinic Index (n=32), positive PB samples were found in 25%, 62% and 73% of cases with scores of 0, 1 and 2, respectively. Median (range) percentage and absolute cPC numbers (per µL) were of 13 to 16 and 10 to 200 times lower (p<0.0001) in MGUS -0.0002% (<0.0001%-0.05450%) and 0.011 cPC/µL (range: <0.0001 cPC/µL -3.2 cPC/µL)- than in SMM -0.0026% (0.00020%-0.23%) and 0.14 cPC/µL (range: 0.022 cPC/µL - 14.58 cPC/µL) and MM -0.0033% (0.00064%-1.05%) and 2.01 cPC/µL (range: 0.043 cPC/µL -103.8 cPC/µL)-, respectively. Interestingly, a clear relationship was found between the presence of circulating cPC in PB of both MGUS, SMM and MM cases, and BM involvement by >60% of cPCs within the PC BM compartment (R2= 0.75; n=66). The cut-off obtained to distinguish between MM and MGUS cases according to the percentage and absolute number of cPCs circulating in PB was of 0.0009% and 0.055 cPC/µL with a sensitivity of 93% and 86%, and a specificity of 75% and 75% for relative and absolute numbers, respectively.

Conclusions: The EuroFlow-IMF NGF-MM MRD panel and approach are well-suited for high sensitive detection of circulating cPC in the PB of virtually every newly-diagnosed MM and SMM patient and the majority of MGUS cases, particularly among MGUS at higher risk of malignant progression; interestingly in both patients groups, the presence of PB involvement and its levels were closely associated with the degree of involvement of the BM PC compartment by cPC.

* Both authors have contributed similarly to this work and they should both be considered as first author.

Disclosures: Paiva: EngMab AG: Research Funding ; Celgene: Consultancy ; Janssen: Consultancy ; Millenium: Consultancy ; Binding Site: Consultancy ; Sanofi: Consultancy ; BD Bioscience: Consultancy ; Onyx: Consultancy . Puig: Janssen: Consultancy ; The Binding Site: Consultancy . Mateos: Celgene: Consultancy , Honoraria ; Takeda: Consultancy ; Onyx: Consultancy ; Janssen-Cilag: Consultancy , Honoraria . Durie: Celgene: Consultancy ; Onyx: Consultancy ; Takeda: Consultancy ; Johnson and Johnson: Consultancy . van Dongen: BD Biosciences (cont'd): Other: Laboratory Services in the field of technical validation of EuroFlow-OneFlow antibody tubes in dried format. The Laboratory Services are provided by the Laboratory of Medical Immunology, Dept. of Immunology, Erasmus MC, Rotterdam, NL ; Cytognos: Patents & Royalties: Licensing of IP on Infinicyt software, Patents on EuroFlow-based flowcytometric Diagnosis and Classification of hematological malignancies, Patents on MRD diagnostics, and Patents on PID diagnostics. ; Cytognos (continued): Patents & Royalties: Royalty income for EuroFlow Consortium. The Infinicyt software is provided to all EuroFlow members free-of-charge.Licensing of Patent on detection of IgE+ B-cells in allergic diseases. Royalties for Dept. of Immunology, Erasmus MC, Rotterdam, NL ; DAKO: Patents & Royalties: Licensing of IP and Patent on Split-Signal FISH. Royalties for Dept. of Immunology, Erasmus MC, Rotterdam, NL ; InVivoScribe: Patents & Royalties: Licensing of IP and Patent on BIOMED-2-based methods for PCR-based Clonality Diagnostics.. Royalty income for EuroClonality-BIOMED-2 Consortium ; Immunostep: Patents & Royalties: Licensing of IP and Patents on immunobead-based dection of fusion proteins in acute leukemias and other tumors. Royalties for Dept. of Immunology, Erasmus MC and for EuroFlow Consortium ; BD Biosciences: Other: Educational Services: Educational Lectures and Educational Workshops (+ related travelling costs). The lectures and workshops fully focus on the scientific achievements of the EuroFlow Consortium (No advertisement of products of BD Biosciences). , Patents & Royalties: Licensing of IP and Patent on EuroFlow-based flowcytometric Diagnosis and Classification of hematological malignancies; Royalty income for EuroFlow Consortium. ; Roche: Consultancy , Other: Laboratory Services in the field of MRD diagnostics, provided by the Laboratory of Medical Immunology, Dept. of Immunology, Erasmus MC, Rotterdam, NL. . San Miguel: Janssen-Cilag: Honoraria ; Onyx: Honoraria ; Millennium: Honoraria ; Bristol-Myers Squibb: Honoraria ; Celgene: Honoraria ; Novartis: Honoraria ; Sanofi-Aventis: Honoraria .

*signifies non-member of ASH